JG1772
A key component of Galland know-how, the section insulator has been the subject of many hours of R&D. We have extended our range and developed our systems alongside major railway players in France and internationally. Our goal is to meet our customers' demands through high-performance, durable and easy-to-install systems.
The JG1772 section insulator is designed for conventional catenary type infrastructures supplied with 1500 V DC up to 3000 V DC.
Category : Section insulator
Voltage(s): 1500 V DC, 3000 V DC
Keyword(s): IS, insulator, electrical sectioning
| JG1772 | |
|---|---|
| Crossing speed | 200 km/h |
| Air blade | 60 mm |
| Vanishing line | 400 mm |
| Max workload. | 40 kN |
| Max breaking load. | 120 kN |
| Reference standards | EN 50119 - EN 50124 |
| Length - L | 1045 mm |
| Width - W | 129 mm |
| Height - H | 200 mm |
| Mass | 10.4 kg |
| Number of FC | 1 |

Specific Sets / Options
| Landmark | Designation |
|---|---|
| /101 | 1FC - With non-insulated suspensions |
| /102 | 1FC - With 2 non-insulated suspensions |
| /201 | 2FC - With non-insulated suspensions |
| /202 | 2FC - With 2 non-insulated suspensions |
| /205 | 2 FC - With 2 isolated suspensions |
| /215 | 2 FC - With 1 isolated suspension |
Associated tools
| Ref. | Designation |
|---|---|
| JG1855 | Laying device |
| N73003 | Hydraulic pump |
| JG1873 | Adjustment template |