JG2178
A key component of Galland know-how, the section insulator has been the subject of many hours of R&D. We have extended our range and developed our systems alongside major railway players in France and internationally. Our goal is to meet our customers' demands through high-performance, durable and easy-to-install systems.
The JG2178 section insulator is intended for conventional catenary (1500 V DC) or tramway (750 V DC) type infrastructures.
Category : Section insulator
Voltage(s): 1500 V DC
Keyword(s): IS, insulator, electrical sectioning
| JG2178/10x or /20x | JG2178/30x or /40x | |
|---|---|---|
| Crossing speed | 200 km/h | 110-140 km/h |
| Air blade | 32 mm | 36 mm |
| Vanishing line | 400 mm | 400 mm |
| Max workload. | 40 kN | 40 kN |
| Max breaking load. | 120 kN | 120 kN |
| Reference standards | EN 50119 - EN 50124 | EN 50119 - EN 50124 |
| Length - L | 1045 mm | 1060 mm |
| Width - W | 129 mm | 129 mm |
| Height - H | 200 mm | 380 mm |
| Mass | 10.5 kg | 13.5 kg |
| Number of FC | 1 or 2 | 1 or 2 |

Specific Sets / Options
| Landmark | Designation |
|---|---|
| /101 | 1FC - Without suspensions |
| /102 | 1FC - With suspensions |
| /201 | 2FC - Without suspensions |
| /202 | 2FC - With suspensions |
| /301 | 1 FC - With preferential direction - Without suspensions |
| /302 | 1 FC - With preferential direction - With suspensions |
| /401 | 2 FC - With preferential direction - Without suspensions |
| /402 | 2 FC - With preferential direction - With suspensions |
Associated tools
| Ref. | Designation |
|---|---|
| JG1855 | Laying device |
| N73003 | Hydraulic pump |
| JG1873 | Adjustment template |